| Our Products... |
- Servo Stabilizer
- Three Phase Air Cooled
-
Isolation Transformer
- Electronic Voltage Stabilizers
TECHNICAL SPECIFICATIONS FOR SERVO STABILIZER |
1. |
Capacity : |
25 to 1200 KVA 3PH |
2. |
Input Voltage Range : |
340 V - 470 V AC 3phase |
3. |
Output Voltage : |
415 V +/- 1% ph to ph (240v phase) |
4. |
No. of phases : |
Three |
5. |
Line Frequency : |
47-53Hz. |
6. |
Output Voltage Regulation : |
+1% |
7. |
Type of Cooling : |
Oil Cooled |
8. |
Type : |
Unbalanced supply and Load conditions |
9. |
Efficiency : |
>95% |
10. |
Speed of Correction : |
30 V per sec. |
11. |
Wave form distortion : |
Nil |
12. |
Effect of Load power factor : |
Nil |
13. |
Ambient Temperature : |
0-40ºC |
14. |
Duty Cycle : |
Continuous |
15. |
Indications on each phase : |
Input on,Input Low,Input High,Output On,Output Cutoff. |
16. |
Controls on each Phase : |
Auto/Manual Selector Switch,Increase/Decrease Selector Switch,Volts adj. Potentiometer. |
17. |
Metering : |
Voltmeter to read Input and Output Voltages with selector switch, Ammeter to read the Output current. |
18. |
Other Indications &Controls : |
Input R, Y, B Indications in each ph 3phOutput on Indication,Reset Auto/Manual selector switch Output On Switch Output off Switch. |
19. |
Protection : |
Low Voltage Protection,High Voltage Protection,Over load Protection,Short Circuit Protection,
Single Phase Preventer. |
|
|
|
Electronic Servo Controlled Voltage Stabilizers Single Phase -
1KVA to 20 KVA (Air Cooled) Three Phase Air Cooled Capacity 3 KVA to 60 KVA
|
1. |
Capacity : |
3 to 60 KVA 3PH |
2. |
Input Voltage Range : |
340 V - 470 V AC 3phase |
3. |
Output Voltage : |
415 V +/- 1% ph to ph (240v phase) |
4. |
No. of phases : |
Three |
5. |
Line Frequency : |
47-53Hz. |
6. |
Output Voltage Regulation : |
+1% |
7. |
Type of Cooling : |
Air Cooled |
8. |
Type : |
Unbalanced supply and Load conditions |
9. |
Efficiency : |
>95% |
10. |
Speed of Correction : |
30 V per sec. |
11. |
Wave form distortion : |
Nil |
12. |
Effect of Load power factor : |
Nil |
13. |
Ambient Temperature : |
0-40ºC |
14. |
Duty Cycle : |
Continuous |
15. |
Indications on each phase : |
Input on,Input Low,Input High,Output On,Output Cutoff. |
16. |
Controls on each Phase : |
Auto/Manual Selector Switch,Increase/Decrease Selector Switch,Volts adj. Potentiometer. |
17. |
Metering : |
Digital Voltmeter to read Input and Output Voltages with selector switch. Ammeter to read the Output current
|
18. |
Other Indications &Controls : |
Input R, Y, B Indications in each ph 3phOutput on Indication,Reset Auto/Manual selector switch Output On Switch Output off Switch. |
19. |
Protection : |
Low Voltage Protection,High Voltage Protection,Over load Protection,Short Circuit Protection,
Single Phase Preventer. |
|
|
Isolation Transformer Technical Specifications |
1. |
Primary voltage : |
230V, 50 Hz, 1  or 400V, 50Hz, 3 |
2. |
Secondary Voltage : |
230V, 50 Hz, 1  or 400V, 50 Hz, 3  |
3. |
Input range (Allowable) : |
+ 10% |
4. |
Load Regulation : |
3.5 to 7% |
5. |
Mode of Operation : |
1: 1 or Stepdown or Stepup |
6. |
A.C. Breakdown voltage test : |
2500 V for one minute |
7. |
Line Frequency : |
50Hz + 3Hz Insulation Re meg. ohm at 500 V.D.C. for one minute. |
8. |
Common mode Noise Rejection : |
Better than 85 db |
9. |
Differential Mode Noise Rejection : |
Better than 50 db |
|
|
Isolation Transformers are available from 0.5 KVA to 30 KVA as standard models. Three Phase (Delta/Star) Isolation Transformers can be supplied upto 500 KVA as per customer specifications. |
* Rectifiers for Anodizing / Electroplating
* Other Electronic Custom-Built Equipments |
|
Electronic Voltage Stabilizers for Air Conditioners, Freezers Technical Specifications |
1. |
Input Voltage Range : |
170V-270V Output 9% (200V - 240V) |
2. |
Out Voltage : |
220V + 9% (200V - 240V) |
3. |
Protections : |
Over voltage / Under voltage Trip |
4. |
Time Delay Facility : |
Electronic Time Delay (20 - 200 sec) to switch on the output after restoring normality. |
5. |
Termination : |
Input : Power chord (Rated)
Output : 30Amps/3 pin connector |
6. |
Metering : |
0-300V Voltmeter with selector switch to read input and output voltages. |
7. |
Indications : |
(a) Input On (b) Output On (c) OV/UV Trip |
|
|
|
|
 |
|